Vista de pagina 115
DSP_minerror
4-88
Special Requirements Array GSP0_TABLE[] must be double-word aligned.
Implementation Notes
- Bank Conflicts: No bank conflicts occur.
- Interruptibility: The code is interrupt-tolerant but not interruptible.
- The load double-word instruction is used to simultaneously load four
values in a single clock cycle.
- The inner loop is completely unrolled.
- The outer loop is 4 times unrolled.
Benchmarks Cycles 256/4 * 9 + 17 = 593
Codesize 352 bytes