Texas-instruments TMS320C3x Manual de usuario Pagina 661

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 757
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 660
Round Floating-Point Value
RND
13-203
Assembly Language Instructions
Example RND R5,R2
Before Instruction After Instruction
R2 00 0000 0000 R2 07 33C1 6F00
R5 07 33C1 6EEF R5 07 33C1 6EEF
LUF 0 LUF 0
LV 0 LV 0
UF 0 UF 0
N 0 N 0
Z 0 Z 0
V 0 V 0
C 0 C 0
1.79755599e+02
1.79755599e+02
1.79755600e+02
Note: BZUF Instruction
If a BZ instruction is executed immediately following an RND instruction with
a 0 operand, the branch is not performed because the zero flag is not set.
To circumvent this problem, execute a BZUF instruction instead of a BZ
instruction.